Conversion steps

  1. Add VDOM(s) to the SLBC primary worker with names that match those of the FGCP cluster.
  2. Map FGCP cluster interface names to SLBC primary worker interfaces names. For example you could map the FGCP cluster port1 and port2 interfaces to the SLBC primary worker fctl/f1 and fctl/f2 interfaces. You can also include aggregate interfaces in this mapping and you can also map FGCP cluster interfaces to SLBC trunks.
  3. Add interfaces to the SLBC primary worker VDOMs according to your mapping. This includes moving SLBC physical interfaces into the appropriate VDOMs, creating aggregate interfaces, and creating SLBC trunks if required.
  4. Add VLANs to the SLBC primary worker that match VLANs in the FGCP cluster. They should have the same names as the FGCP VLANs, be added to the corresponding SLBC VDOMs and interfaces, and have the same VLAN IDs.
  5. Add inter-VDOM links to the SLBC primary worker that match the FGCP cluster.
  6. Backup the configuration of each FGCP cluster VDOM.
  7. Backup the configuration of each SLBC primary worker VDOM.
  8. Use a text editor to replace the first 4 lines of each FGCP cluster VDOM configuration file with the first four lines of the corresponding SLBC primary worker VDOM configuration file. Here are example lines from an SLBC primary worker VDOM configuration file:

    #config-version=FG-5KB-5.02-FW-build670-150318:opmode=0:vdom=1:user=admin

    #conf_file_ver=2306222306838080295

    #buildno=0670

    #global_vdom=0:vd_name=VDOM1

  9. With a text editor edit each FGCP cluster VDOM configuration file and replace all FGCP cluster interface names with the corresponding SLBC worker interfaces names according to the mapping you created in step 2.
  10. Set up a console connection to the SLBC primary worker to check for errors during the following steps.
  11. From the SLBC primary worker, restore each FGCP cluster VDOM configuration file to each corresponding SLBC primary worker VDOM.
  12. Check the following on the SLBC primary worker:

    • Make sure set type fctrl-trunk is enabled for SLBC trunk interfaces.
    • Enable the global and management VDOM features that you need including SNMP, logging, connections to FortiManager, FortiAnalyzer, and so on.
    • If there is a FortiController in chassis slot 2, make sure the worker base2 interface status is up.
    • Remove snmp-index entries for each interface.
    • Since you can manage the workers from the FortiController you can remove management-related configurations using the worker mgmt1 and mgmt2 interfaces (Logging, SNMP, admin access, etc.) if you are not going to use these interfaces for management.

Conversion steps

  1. Add VDOM(s) to the SLBC primary worker with names that match those of the FGCP cluster.
  2. Map FGCP cluster interface names to SLBC primary worker interfaces names. For example you could map the FGCP cluster port1 and port2 interfaces to the SLBC primary worker fctl/f1 and fctl/f2 interfaces. You can also include aggregate interfaces in this mapping and you can also map FGCP cluster interfaces to SLBC trunks.
  3. Add interfaces to the SLBC primary worker VDOMs according to your mapping. This includes moving SLBC physical interfaces into the appropriate VDOMs, creating aggregate interfaces, and creating SLBC trunks if required.
  4. Add VLANs to the SLBC primary worker that match VLANs in the FGCP cluster. They should have the same names as the FGCP VLANs, be added to the corresponding SLBC VDOMs and interfaces, and have the same VLAN IDs.
  5. Add inter-VDOM links to the SLBC primary worker that match the FGCP cluster.
  6. Backup the configuration of each FGCP cluster VDOM.
  7. Backup the configuration of each SLBC primary worker VDOM.
  8. Use a text editor to replace the first 4 lines of each FGCP cluster VDOM configuration file with the first four lines of the corresponding SLBC primary worker VDOM configuration file. Here are example lines from an SLBC primary worker VDOM configuration file:

    #config-version=FG-5KB-5.02-FW-build670-150318:opmode=0:vdom=1:user=admin

    #conf_file_ver=2306222306838080295

    #buildno=0670

    #global_vdom=0:vd_name=VDOM1

  9. With a text editor edit each FGCP cluster VDOM configuration file and replace all FGCP cluster interface names with the corresponding SLBC worker interfaces names according to the mapping you created in step 2.
  10. Set up a console connection to the SLBC primary worker to check for errors during the following steps.
  11. From the SLBC primary worker, restore each FGCP cluster VDOM configuration file to each corresponding SLBC primary worker VDOM.
  12. Check the following on the SLBC primary worker:

    • Make sure set type fctrl-trunk is enabled for SLBC trunk interfaces.
    • Enable the global and management VDOM features that you need including SNMP, logging, connections to FortiManager, FortiAnalyzer, and so on.
    • If there is a FortiController in chassis slot 2, make sure the worker base2 interface status is up.
    • Remove snmp-index entries for each interface.
    • Since you can manage the workers from the FortiController you can remove management-related configurations using the worker mgmt1 and mgmt2 interfaces (Logging, SNMP, admin access, etc.) if you are not going to use these interfaces for management.