Interface packet capture
You can perform packet capture on a managed FortiGate's interface through the device database.
To perform a packet capture on managed FortiGate interfaces:
- In Device Manager, select a FortiGate and go to Network> Interfaces.
- Select an interface, click More > Packet Capture.
- You can configure the Max Number of Packets and/or Filters, and click OK to start the packet capture.
If Max Number of Packets is not specified, the packet capture will stop after 50000 packets to preserve memory. - Select Graph, Headers, or Packet Data to view details of the packet.
- Optionally, click Save as PCAP to save the file in the .pcap format.