config system ignition-sensing
Description: Configure ignition sensing on FEV 211/212F models.
config system ignition-sensing
set status {enable | disable}
set poweroff-delay <integer>
end
Sample command:
config system ignition-sensing
set status enable
set poweroff-delay 60
end
| status |
The digital state that will be set when the alert is detected. |
option |
- |
enable |
|
|
| enable |
The device will automatically shut down under the following conditions:
- The power supply voltage is 12V and the ignition sense pin on the power supply is not connected to 12V.
- The power supply voltage is 24V and the ignition sense pin on the power supply is not connected to 24V.
|
|
disable
|
The device will not automatically shut down, and will automatically turn on if already shut down under the following conditions:
|
|
If you are using a cigarette lighter socket to power the device and encounter an unexpected shutdown, set the status to disable.
|
|
| poweroff-delay |
Delay powering off the device after this interval (in seconds). |
integer |
0 - 86400 |
600 |