config switch-controller flow-tracking
Configure FortiSwitch flow tracking and export via ipfix/netflow.
config switch-controller flow-tracking
Description: Configure FortiSwitch flow tracking and export via ipfix/netflow.
set sample-mode [local|perimeter|...]
set sample-rate {integer}
set format [netflow1|netflow5|...]
set collector-ip {ipv4-address}
set collector-port {integer}
set transport [udp|tcp|...]
set level [vlan|ip|...]
set max-export-pkt-size {integer}
set timeout-general {integer}
set timeout-icmp {integer}
set timeout-max {integer}
set timeout-tcp {integer}
set timeout-tcp-fin {integer}
set timeout-tcp-rst {integer}
set timeout-udp {integer}
config aggregates
Description: Configure aggregates in which all traffic sessions matching the IP Address will be grouped into the same flow.
edit <id>
set ip {ipv4-classnet}
next
end
end
config switch-controller flow-tracking
Parameter |
Description |
Type |
Size |
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
sample-mode |
Configure sample mode for the flow tracking. |
option |
- |
|||||||||||||
|
|
|||||||||||||||
sample-rate |
Configure sample rate for the perimeter and device-ingress sampling. |
integer |
Minimum value: 0 Maximum value: 99999 |
|||||||||||||
format |
Configure flow tracking protocol. |
option |
- |
|||||||||||||
|
|
|||||||||||||||
collector-ip |
Configure collector ip address. |
ipv4-address |
Not Specified |
|||||||||||||
collector-port |
Configure collector port number. |
integer |
Minimum value: 0 Maximum value: 65535 |
|||||||||||||
transport |
Configure L4 transport protocol for exporting packets. |
option |
- |
|||||||||||||
|
|
|||||||||||||||
level |
Configure flow tracking level. |
option |
- |
|||||||||||||
|
|
|||||||||||||||
max-export-pkt-size |
Configure flow max export packet size . |
integer |
Minimum value: 512 Maximum value: 9216 |
|||||||||||||
timeout-general |
Configure flow session general timeout . |
integer |
Minimum value: 60 Maximum value: 604800 |
|||||||||||||
timeout-icmp |
Configure flow session ICMP timeout . |
integer |
Minimum value: 60 Maximum value: 604800 |
|||||||||||||
timeout-max |
Configure flow session max timeout . |
integer |
Minimum value: 60 Maximum value: 604800 |
|||||||||||||
timeout-tcp |
Configure flow session TCP timeout . |
integer |
Minimum value: 60 Maximum value: 604800 |
|||||||||||||
timeout-tcp-fin |
Configure flow session TCP FIN timeout . |
integer |
Minimum value: 60 Maximum value: 604800 |
|||||||||||||
timeout-tcp-rst |
Configure flow session TCP RST timeout . |
integer |
Minimum value: 60 Maximum value: 604800 |
|||||||||||||
timeout-udp |
Configure flow session UDP timeout . |
integer |
Minimum value: 60 Maximum value: 604800 |
config aggregates
Parameter |
Description |
Type |
Size |
---|---|---|---|
ip |
IP address to group all matching traffic sessions to a flow. |
ipv4-classnet |