config switch-controller system
Configure system-wide switch controller settings.
config switch-controller system
Description: Configure system-wide switch controller settings.
set parallel-process-override [disable|enable]
set parallel-process {integer}
set data-sync-interval {integer}
set iot-weight-threshold {integer}
set iot-scan-interval {integer}
set iot-holdoff {integer}
set iot-mac-idle {integer}
set nac-periodic-interval {integer}
set dynamic-periodic-interval {integer}
set tunnel-mode [compatible|strict]
end
config switch-controller system
Parameter |
Description |
Type |
Size |
Default |
||||||
---|---|---|---|---|---|---|---|---|---|---|
parallel-process-override |
Enable/disable parallel process override. |
option |
- |
disable |
||||||
|
|
|||||||||
parallel-process |
Maximum number of parallel processes. |
integer |
Minimum value: 1 Maximum value: 32 ** |
1 |
||||||
data-sync-interval |
Time interval between collection of switch data . |
integer |
Minimum value: 30 Maximum value: 1800 |
60 |
||||||
iot-weight-threshold |
MAC entry's confidence value. Value is re-queried when below this value . |
integer |
Minimum value: 0 Maximum value: 255 |
1 |
||||||
iot-scan-interval |
IoT scan interval . |
integer |
Minimum value: 2 Maximum value: 10080 |
60 |
||||||
iot-holdoff |
MAC entry's creation time. Time must be greater than this value for an entry to be created . |
integer |
Minimum value: 0 Maximum value: 10080 |
5 |
||||||
iot-mac-idle |
MAC entry's idle time. MAC entry is removed after this value . |
integer |
Minimum value: 0 Maximum value: 10080 |
1440 |
||||||
nac-periodic-interval |
Periodic time interval to run NAC engine . |
integer |
Minimum value: 5 Maximum value: 60 |
15 |
||||||
dynamic-periodic-interval |
Periodic time interval to run Dynamic port policy engine . |
integer |
Minimum value: 5 Maximum value: 60 |
15 |
||||||
tunnel-mode |
Compatible/strict tunnel mode. |
option |
- |
compatible |
||||||
|
|
** Values may differ between models.