Resolved issues
The following issues have been resolved in FortiADC 7.4.8 release. For inquiries about particular bugs, please contact Fortinet Customer Service & Support.
|
Bug ID |
Description |
|---|---|
| 1160460 | SCEP certificate retrieval fails when the server returns a full certificate chain containing multiple certificates. |
| 1150240 | FortiADC (secondary) enters a reboot loop when connected to the network with the heartbeat interface active, triggered by a buffer overflow caused by an excessively long certificate file name. |
| 1145394 | Configured DNS settings are overridden by default nameserver in AWS. |
| 1131903 | FortiADC returns <MISSING> in the SNMP response for sysinfo queries, resulting in incomplete system information retrieval. |
| 1116520 | HTTP/2 requests to a specific URL result in timeouts, whereas HTTP/1.1 works without issue. This is due to delays in data transmission caused by HTTP/2 waiting for window updates. Internal adjustments to httproxy's send-state flags were made to improve alignment with HTTP/2 flow control, reducing the likelihood of transmission stalls due to insufficient window size. |
| 1048845/0942554 | FortiADC primary device crashed and rebooted due to a refcnt overflow in fib_stats, leading to system instability and core dump generation. |