Fortinet white logo
Fortinet white logo

Resolved issues

Resolved issues

The following issues have been resolved in FortiADC 7.6.5 release. For inquiries about particular bugs, please contact Fortinet Customer Service & Support.

Bug ID

Description

1226241 A system crash occurred under heavy DNS traffic on L4 UDP/TCP virtual servers using full NAT with a small SNAT pool. When the system attempted to allocate a local source port, most available ports were already in use, triggering excessive port-search loops and a resulting kernel soft lockup.
1224907 On the AWS platform, restoring a configuration file caused HA settings to be lost after reboot. The issue occurred because the HA hb-typeunicast option was not parsed during the restore process.
1221882 In Advanced Bot Protection (ABP), JavaScript insertion failed when the HTML <head> tag included attributes (for example, <head id="xxx">). Only a plain <head></head> tag was recognized.
1219059 The GUI became inaccessible with a “Cannot allocate memory” error after long uptime. OSPF generated excessive error logs for virtual server IP addresses on bridge interfaces, filling the /tmp directory and preventing the GUI from loading.
1218158 Enabling compression on an L7 HTTPS virtual server together with diagnose debug for httproxy caused the process to crash due to invalid data access in the debug-printing code.
1214530 After upgrade, some VDOMs showed inactive routes and all virtual servers in those VDOMs were down. rtmd did not receive interface address and link-status updates correctly when an interface IP overlapped with a load-balance IP pool, causing the routing state to be reported incorrectly.
1213980 In a VRRP Active-Active cluster, cloning a global DNS policy with a large number of A/AAAA records caused the primary node’s Web GUI to hang and return “Bad Gateway” errors.
1212271 New CLI options are added to adjust the physical interface ring buffer size. Administrators can now configure rxring and txring values under config system interface and verify settings with the diagnose hardware get deviceinfo nic-ringsize command.
1210252 Dynamic real server pools using the Kubernetes SDN connector failed to import members when large clusters were used. Duplicate node entries and command-size limits prevented real server and pool-member configuration from being saved, causing the pool to remain empty.
1208659 HA synchronization failed when an administrator account was changed to a global user while referencing a RADIUS server configured in a non-root VDOM. The mismatch prevented the configuration from applying on the primary node and caused HA sync to stop.
1205865 The virtual-server-l2-cache-timeout setting under config router setting did not take effect in non-root VDOMs. The value was treated as a global parameter, so only the root VDOM configuration was applied.

1205106

In the GUI, the Add Filter option under Network Security > Firewall was incorrectly grayed out and unavailable.

1200598

When HTTPS service was enabled on port2 and port3 in an Active-Active HA cluster, a node could drop out of the cluster due to a GLB process binding failure during HA synchronization. The issue caused temporary cluster instability until the node rejoined.

1156935 Support for displaying PSU information on FortiADC 420F was added to the hardware monitor, including PSU status, temperature, fan speed, and voltage readings.
1049328 SNMP queries returned empty data for VLAN interfaces due to ethtool not reporting interface statistics.

Resolved issues

Resolved issues

The following issues have been resolved in FortiADC 7.6.5 release. For inquiries about particular bugs, please contact Fortinet Customer Service & Support.

Bug ID

Description

1226241 A system crash occurred under heavy DNS traffic on L4 UDP/TCP virtual servers using full NAT with a small SNAT pool. When the system attempted to allocate a local source port, most available ports were already in use, triggering excessive port-search loops and a resulting kernel soft lockup.
1224907 On the AWS platform, restoring a configuration file caused HA settings to be lost after reboot. The issue occurred because the HA hb-typeunicast option was not parsed during the restore process.
1221882 In Advanced Bot Protection (ABP), JavaScript insertion failed when the HTML <head> tag included attributes (for example, <head id="xxx">). Only a plain <head></head> tag was recognized.
1219059 The GUI became inaccessible with a “Cannot allocate memory” error after long uptime. OSPF generated excessive error logs for virtual server IP addresses on bridge interfaces, filling the /tmp directory and preventing the GUI from loading.
1218158 Enabling compression on an L7 HTTPS virtual server together with diagnose debug for httproxy caused the process to crash due to invalid data access in the debug-printing code.
1214530 After upgrade, some VDOMs showed inactive routes and all virtual servers in those VDOMs were down. rtmd did not receive interface address and link-status updates correctly when an interface IP overlapped with a load-balance IP pool, causing the routing state to be reported incorrectly.
1213980 In a VRRP Active-Active cluster, cloning a global DNS policy with a large number of A/AAAA records caused the primary node’s Web GUI to hang and return “Bad Gateway” errors.
1212271 New CLI options are added to adjust the physical interface ring buffer size. Administrators can now configure rxring and txring values under config system interface and verify settings with the diagnose hardware get deviceinfo nic-ringsize command.
1210252 Dynamic real server pools using the Kubernetes SDN connector failed to import members when large clusters were used. Duplicate node entries and command-size limits prevented real server and pool-member configuration from being saved, causing the pool to remain empty.
1208659 HA synchronization failed when an administrator account was changed to a global user while referencing a RADIUS server configured in a non-root VDOM. The mismatch prevented the configuration from applying on the primary node and caused HA sync to stop.
1205865 The virtual-server-l2-cache-timeout setting under config router setting did not take effect in non-root VDOMs. The value was treated as a global parameter, so only the root VDOM configuration was applied.

1205106

In the GUI, the Add Filter option under Network Security > Firewall was incorrectly grayed out and unavailable.

1200598

When HTTPS service was enabled on port2 and port3 in an Active-Active HA cluster, a node could drop out of the cluster due to a GLB process binding failure during HA synchronization. The issue caused temporary cluster instability until the node rejoined.

1156935 Support for displaying PSU information on FortiADC 420F was added to the hardware monitor, including PSU status, temperature, fan speed, and voltage readings.
1049328 SNMP queries returned empty data for VLAN interfaces due to ethtool not reporting interface statistics.