config switch-controller stp-settings

config switch-controller stp-settings

Configure FortiSwitch spanning tree protocol (STP).

config switch-controller stp-settings

Description: Configure FortiSwitch spanning tree protocol (STP).

set name {string}

set revision {integer}

set hello-time {integer}

set forward-time {integer}

set max-age {integer}

set max-hops {integer}

set pending-timer {integer}

end

config switch-controller stp-settings

Parameter

Description

Type

Size

Default

name

Name of global STP settings configuration.

string

Maximum length: 31

revision

STP revision number .

integer

Minimum value: 0 Maximum value: 65535

0

hello-time

Period of time between successive STP frame Bridge Protocol Data Units .

integer

Minimum value: 1 Maximum value: 10

2

forward-time

Period of time a port is in listening and learning state .

integer

Minimum value: 4 Maximum value: 30

15

max-age

Maximum time before a bridge port saves its configuration BPDU information .

integer

Minimum value: 6 Maximum value: 40

20

max-hops

Maximum number of hops between the root bridge and the furthest bridge .

integer

Minimum value: 1 Maximum value: 40

20

pending-timer

Pending time .

integer

Minimum value: 1 Maximum value: 15

4

config switch-controller stp-settings

config switch-controller stp-settings

Configure FortiSwitch spanning tree protocol (STP).

config switch-controller stp-settings

Description: Configure FortiSwitch spanning tree protocol (STP).

set name {string}

set revision {integer}

set hello-time {integer}

set forward-time {integer}

set max-age {integer}

set max-hops {integer}

set pending-timer {integer}

end

config switch-controller stp-settings

Parameter

Description

Type

Size

Default

name

Name of global STP settings configuration.

string

Maximum length: 31

revision

STP revision number .

integer

Minimum value: 0 Maximum value: 65535

0

hello-time

Period of time between successive STP frame Bridge Protocol Data Units .

integer

Minimum value: 1 Maximum value: 10

2

forward-time

Period of time a port is in listening and learning state .

integer

Minimum value: 4 Maximum value: 30

15

max-age

Maximum time before a bridge port saves its configuration BPDU information .

integer

Minimum value: 6 Maximum value: 40

20

max-hops

Maximum number of hops between the root bridge and the furthest bridge .

integer

Minimum value: 1 Maximum value: 40

20

pending-timer

Pending time .

integer

Minimum value: 1 Maximum value: 15

4