config system virtual-switch
This command is available for reference model(s) FortiGate 140E-POE, FortiWiFi 61F. It is not available for FortiGate 601E, FortiGate 2201E, FortiGate VM64. |
Configure virtual hardware switch interfaces.
config system virtual-switch
Description: Configure virtual hardware switch interfaces.
edit <name>
set physical-switch {string}
set vlan {integer}
config port
Description: Configure member ports.
edit <name>
set alias {string}
set poe [enable|disable]
next
end
set span [disable|enable]
set span-source-port {string}
set span-dest-port {string}
set span-direction [rx|tx|...]
next
end
config system virtual-switch
Parameter |
Description |
Type |
Size |
Default |
||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
physical-switch |
Physical switch parent. |
string |
Not Specified |
|
||||||||
vlan * |
VLAN. |
integer |
Minimum value: 0 Maximum value: 4294967295 |
0 |
||||||||
span |
Enable/disable SPAN. |
option |
- |
disable |
||||||||
|
|
|||||||||||
span-source-port |
SPAN source port. |
string |
Not Specified |
|
||||||||
span-dest-port |
SPAN destination port. |
string |
Not Specified |
|
||||||||
span-direction |
SPAN direction. |
option |
- |
both |
||||||||
|
|
* This parameter may not exist in some models.
config port
Parameter |
Description |
Type |
Size |
Default |
||||||
---|---|---|---|---|---|---|---|---|---|---|
alias |
Alias. |
string |
Not Specified |
|
||||||
poe * |
Enable/disable PoE status. |
option |
- |
enable |
||||||
|
|