Fortinet black logo

Resolved issues

Resolved issues

The following issues have been fixed in FortiSwitchOS 7.2.5. For inquiries about a particular bug, please contact Customer Service & Support.

Bug ID Description
860773 The output of the diagnose sys psu status command is wrong for the FSR-112D-POE model when both power supply units (PSUs) are connected and on.
866288 ACLs should work correctly on the FS-3032E model.
878762 A VLAN interface labeled mgmt causes the GUI to crash frequently.
889987

When the port descriptions are too long, a “500 Internal Server Error” is reported.

891323 Going to the Router > Config > OSPF > Areas page results in an Internal Server Error.
896010 The FS-524D and FS-524D-FPOE models will assign two split ports with the same physical MAC address.

896925

After configuring the set edge-port disabled command, “BPDU Guard: Resetting <interface_name>” is added to the log.

897887

After enabling the blocking of intra-VLAN traffic on the VLAN, the clients cannot reach the Internet.

898637 The set poe-pre-standard-detect enable command does not work on the FS-124F-FPOE and FS-148F-FPOE models.

902062

After upgrading to FortiSwitchOS 7.2.2, the SFP link between the FS-124E model and the Calix E-9 System randomly turns off.

902493

The FS-148F-FPOE and FS-148F-POE models need to provide power over Ethernet (PoE) power to Cisco phones with Key Expansion Modules (KEMs).

902910

The 2048 key size generated certificate file shows the wrong key size in the CSR decoder.

905384

The IGMP-snooping daemon crashes on the FS-148F model.

906594

The GUI needs to support static IP/32.

909353

The FS-448E, FS-448E-POE, and FS-448E-FPOE models should provide the hardware status and temperature monitoring using the SNMP OIDs.

910257 Going to System > Config > Firmware results in a “500 Internal Server Error.”
917919 The GUI produces an “Internal server error” after an administrator user that is more than 35 characters long tries to log in.

918017

Using RSPAN on managed FSR-112D switches under FortiOS 7.0.11 causes network interruptions.

921600

Unplugging and then plugging in a PC connected to an FS-221E-POE model causes the STP state to change.

922307

The FN-TRAN-SFP-1BU10, FN-TRAN-SFP-1BD10, FN-TRAN-SFP-1BU40, and FN-TRAN-SFP-1BD40 transceivers need to support the auto-module port speed.

Resolved issues

The following issues have been fixed in FortiSwitchOS 7.2.5. For inquiries about a particular bug, please contact Customer Service & Support.

Bug ID Description
860773 The output of the diagnose sys psu status command is wrong for the FSR-112D-POE model when both power supply units (PSUs) are connected and on.
866288 ACLs should work correctly on the FS-3032E model.
878762 A VLAN interface labeled mgmt causes the GUI to crash frequently.
889987

When the port descriptions are too long, a “500 Internal Server Error” is reported.

891323 Going to the Router > Config > OSPF > Areas page results in an Internal Server Error.
896010 The FS-524D and FS-524D-FPOE models will assign two split ports with the same physical MAC address.

896925

After configuring the set edge-port disabled command, “BPDU Guard: Resetting <interface_name>” is added to the log.

897887

After enabling the blocking of intra-VLAN traffic on the VLAN, the clients cannot reach the Internet.

898637 The set poe-pre-standard-detect enable command does not work on the FS-124F-FPOE and FS-148F-FPOE models.

902062

After upgrading to FortiSwitchOS 7.2.2, the SFP link between the FS-124E model and the Calix E-9 System randomly turns off.

902493

The FS-148F-FPOE and FS-148F-POE models need to provide power over Ethernet (PoE) power to Cisco phones with Key Expansion Modules (KEMs).

902910

The 2048 key size generated certificate file shows the wrong key size in the CSR decoder.

905384

The IGMP-snooping daemon crashes on the FS-148F model.

906594

The GUI needs to support static IP/32.

909353

The FS-448E, FS-448E-POE, and FS-448E-FPOE models should provide the hardware status and temperature monitoring using the SNMP OIDs.

910257 Going to System > Config > Firmware results in a “500 Internal Server Error.”
917919 The GUI produces an “Internal server error” after an administrator user that is more than 35 characters long tries to log in.

918017

Using RSPAN on managed FSR-112D switches under FortiOS 7.0.11 causes network interruptions.

921600

Unplugging and then plugging in a PC connected to an FS-221E-POE model causes the STP state to change.

922307

The FN-TRAN-SFP-1BU10, FN-TRAN-SFP-1BD10, FN-TRAN-SFP-1BU40, and FN-TRAN-SFP-1BD40 transceivers need to support the auto-module port speed.